ISO 9001:2015 certified environmental test systems
HomeProductsDraught Proof
21Luminaire temperature-rise testing

Draught Proof
Chamber.

A standards-aligned black-matt, perforated test enclosure with 16-channel thermocouple logging for controlled temperature-rise evaluation of luminaires and LED products.

16 channels0–300°C measurement1.37 m³IS / IEC lighting tests
Internal size1700 × 900 × 900 mm
Data channels16 Type-K
Measurement range0–300°C
Accuracy±0.5°C or better
Product overview

Measure temperature rise without unwanted air movement.

The draught-proof chamber creates the natural-convection test environment specified for temperature-rise assessment of luminaires, LED lamps, bulbs and associated lighting accessories.

Its double-walled perforated structure, black matt internal finish, test mounting, thermocouples and integrated electrical panel are organised as one repeatable compliance-testing station.

01

Define

Test object, profile and acceptance criteria

Input
02

Condition

Create the required controlled environment

Control
03

Measure

Record the product and chamber response

Evidence
04

Review

Compare results with the approved plan

Decision
Distinctive system logic

Measure temperature rise without unwanted air movement.

The perforated inner wall and black low-reflectivity finish support the prescribed natural-convection environment while sixteen thermocouple channels record the thermal response in real time.

16-CHANNEL TEMPERATURE MAP
T01T08T16
Engineering layers

Performance is built as a complete system.

Review the published performance, construction, control and safety information without losing the technical detail.

System layer 01

Performance

01

Natural convection as required by the stated standards

02

Thermocouple measurement from 0°C to 300°C

03

Accuracy ±0.5°C or better

04

Real-time temperature recording

05

Optional controlled ambient up to 50°C

Key product attributes

Configured around the test—not around a catalogue box.

01

Perforated double-wall enclosure

02

Black matt low-reflectivity interior

03

16-channel data logger

04

Type-K thermocouples

05

Integrated electrical panel

06

Optional ambient heating to 50°C

Technical specifications

Technical datasheet.

Published values are reorganised for clarity. Final performance is subject to the approved chamber configuration, working load and test method.

Values are reproduced from the current ISOTECH technical-datasheet page. Optional ambient heating is included only when specified.
Parameter
Published specification
Notes
Internal dimensions
1700 × 900 × 900 mm
L × W × H
External dimensions
Approx. 1900 × 1100 × 1200 mm
Configuration dependent
Chamber volume
Approx. 1.37 m³
Calculated working enclosure
Temperature channels
16
Type-K thermocouples
Measurement range
0°C to 300°C
Accuracy ±0.5°C or better
Auto transformer
10 A
Panel mounted
Optional heating
Ambient to 50°C
PID controlled
Power supply
230 V / 1 phase / 50 Hz
Connected load approx. 2–3 kW
Application fit

Where this system works.

  • 01Luminaire temperature-rise testing
  • 02LED lamps
  • 03LED bulbs
  • 04Lighting accessories
  • 05Lighting R&D laboratories
  • 06Standards compliance laboratories
Published compliance context

Standards and test methods

Only standards explicitly associated with the current ISOTECH product material are shown. Confirm the edition, clauses, specimen arrangement and acceptance criteria before ordering.

IS 10322 (Part 1): 2014IEC 60598-1 Annex D / Clause 12.4.1IS 16102 (Part 1): 2012, reaffirmed 2017
Engineer the right configuration

Turn your test requirement into a buildable chamber specification.

Share the DUT dimensions, load, operating state, environmental profile, duration, instrumentation, utilities, safety requirements and applicable standard.

Product questions

Draught Proof FAQs.

Answers based on the current ISOTECH product page, reorganised for engineering clarity. Confirm project-specific values in the final proposal.

It provides a controlled natural-convection enclosure for temperature-rise testing of luminaires, LED lamps, bulbs and related lighting accessories.

The low-reflectivity finish forms part of the published construction for controlled luminaire temperature-rise testing.

The published system includes a 16-channel data logger with sixteen Type-K thermocouples.

The thermocouple system is specified from 0°C to 300°C with accuracy of ±0.5°C or better.

Yes. An optional insulated lower heater chamber can provide slow, uniform heating from ambient to 50°C under PID control.

IS 10322 Part 1:2014, IEC 60598-1 Annex D / Clause 12.4.1 and IS 16102 Part 1:2012 (reaffirmed 2017).

Define the test object dimensions, mass, heat load, operating state, required profile, instrumentation, access, utilities and acceptance criteria before selecting the Draught Proof.

Yes. Working volume, ports, shelves or fixtures, controller, monitoring, safety and installation provisions can be engineered around the approved requirement.

The current ISOTECH material describes installation, commissioning, operator training, calibration and maintenance support. Confirm the required scope in the quotation.

Warranty duration and coverage should be confirmed in the commercial proposal for the selected configuration and installation location.